3 technical description, 1 technical specifications, 1 double coil hot water tank: uno/2 – DE DIETRICH INISOL UNO-2 …, UNO-1 … User Manual

Page 5: Technical description, Double coil hot water tank: uno/2

Advertising
background image

5

06/02/12 - 300024525-001-B

UNO/2 200, 300, 400, 500 - UNO/1 200, 300, 400, 500

3 Technical description

3.1 Technical specifications

3.1.1

Double coil hot water tank: UNO/2 ...

UNO/2 200

UNO/2 300

UNO/2 400

UNO/2 500

Water content

litres

200

300

395

500

Top up volume

litres

95

105

165

180

Solar volume

litres

105

195

230

320

Max operating pressure, DHW

bar

10

10

10

10

Boiler heat exchanger

Maximum operating temperature

°C

90

90

90

90

Maximum operating pressure

bar

10

10

10

10

Water content

litres

3.5

4.3

4.9

4.9

Exchange surface

m

2

0.52

0.65

0.72

0.72

Pressure drop

kPa

3.0

3.0

3.4

3.4

Solar exchanger

Water content

litres

3.8

8.1

8.1

10.3

Exchange surface

m

2

0.75

1.2

1.2

1.5

Performance

Primary temperature at 70 °C
Power exchanged

(1) (3)

kW

13.5

16

17.5

17.5

Flow per hour

(1) (3)

l/h

330

390

430

430

Primary temperature at 80 °C
Power exchanged

(1) (3)

kW

17.5

21

23

23

Flow per hour

(1) (3)

l/h

430

515

565

565

Flow in 10 minutes

(2) (3)

l/10 mm

170

190

305

325

Primary temperature at 90 °C
Power exchanged

(1) (3)

kW

22

26

29

29

Flow per hour

(1) (3)

l/h

540

640

712

712

Cooling constant Cr *

Wh/24h·L·K

0.20

0.20

0.19

0.15

* Only in France / Test conducted in accordance with the standard NF D 30-003
(1)

Domestic cold water inlet 10 °C - Domestic hot water outlet 45 °C - Primary flow rate 2 m

3

/h

(2)

Domestic cold water inlet 10 °C - Domestic hot water outlet 40 °C - Domestic hot water storage temperature 65 °C - Primary flow rate 2 m

3

/h

(3)

Values measured only on the back-up volume