2 main parts, Solar hot water tank, Solar station – DE DIETRICH INISOL UNO-2 …, UNO-1 … User Manual

Page 8: Diemasol a regulator

Advertising
background image

8

UNO/2 200, 300, 400, 500 - UNO/1 200, 300, 400, 500

06/02/12 - 300024525-001-B

3.2 Main parts

„

Solar hot water tank

- Tank in enamelled steel
- Solar coil
- Insulation in CFC-free polyurethane foam
- External PVC casing - white

„

Solar station

The solar heating pump unit comprises the solar circuit safety unit, a
pressure and temperature gauge and a flowmeter to visualise
circulation of the solar fluid between the panels and the DHW tank.
An expansion vessel is connected to the solar unit; it is used to
compensate for the expansion of the solar fluid in which the
temperature varies between 0 and 150°C.

„

Diemasol A regulator

The control system is the solar system's brain; it makes the solar
heating pump run at variable speeds according to the difference in
temperature between the bottom of the DHW tank and the solar
panels. The control system manages the set point temperature
(temperature to be attained in the DHW tank), overheating and
nighttime cooling. The control system also displays the various
operating modes, the temperatures in the collectors and in the
bottom of the DHW tank, as well as signalling any malfunctions.

INISOL UNO/2

400-4

2

On roof

ER 154

100014076

UNO/2 400

ER 150

100014071

400

Boiler

EG 101

89807794

2

Roof-integral

Installation

(> 20°)

ER 155

100014077

2

Roof-integral

Installation

(17°)

ER 231

100014741

INISOL UNO/2

400-6

3

On roof

ER 156

100014078

UNO/2 400

ER 150

100014071

400

Boiler

EG 101

89807794

3

Roof-integral

Installation

(> 20°)

ER 157

100014079

3

Roof-integral

Installation

(17°)

ER 232

100014742

CESI System

Array of collectors

Domestic hot water production

Solar fluid

Number of

panels

Type of mounting

package /

Reference

DHW calorifier type

package /

Reference

Volume

(litres)

Back-up type

package /

Reference

Advertising