If the temperature of the central heating water in the boiler falls too

much, the integrated protection device switches itself on:

4

If the water temperature is lower than 7°C, the circulating pump is

activated.

4

If the water temperature is lower than 3°C, the boiler is activated.

4

When the water temperature is above 10 °C, the boiler is switched

off and the circulation pump runs for another 15 minutes.

CAUTION

This function is a protection device for the boiler only, not

for the system or buiding fabric.

CAUTION

If a room thermostat, connected via connectors 7 and 8,

is activated, the boiler will operate permanently until it

reaches the flow setting point.

4.4

Reading out measured values

The following values can be displayed in the information menu Q:

4

t1 =

Flow temperature (°C)

4

t2 =

Return temperature (°C)

4

t3 =

DHW sensor temperature (°C)

This temperature is used only for internal management in DHW

mode. During DHW draw-off, this value does not correspond to

the actual DHW outlet temperature (it is always lower).

4

t4 =

Outside temperature (°C)

4

fl =

Ionization current (μA)

4

Mf =

Fan speed (rpm)

1. Press the f key. The symbol Q flashes.
2. To access the parameters, press key S.
3. Press the [+] key successively to scroll down the various

parameters.

4. Press the > key 2 times to return to the current operating mode

T000138-A

MCR 24/28 BIC

4. Operating the appliance

170513 - 300024112-001-01

18