Problem

Probable causes

Solution

The boiler is not working.

The heating temperature setting

is too low.

Increase the value of parameter p1 or, if a room

thermostat is connected, increase the temperature.

¼See chapter: "Changing the heating

temperature", page 13.

The boiler is not switched on.

4

Check that the boiler is switched on.

4

Check the fuses and switches.

4

Check that the gas valve is fully opened.

The water pressure is too low (<

1 bar).

Top up the installation with water.

¼See chapter:

"Filling the system", page 20.

An error code appears on the

display.

4

Press the Reset button for 2 seconds.

4

Correct the error if possible.

¼See chapter:

"Error codes", page 24.

The gas pressure is too low.

Open the gas valve.

The water pressure is too low

(< 1 bar).

Not enough water in the

installation.

Top up the installation with water.

¼See chapter:

"Filling the system", page 20.

Water leak.

Contact the fitter.

Significant variations in

domestic hot water

temperature.

Insufficient water supply.

Open the valve.

Clicking in the central heating

pipes

The central heating pipe

connections are too tight.

Contact the fitter.

There is air in the heating pipes. It is essential that you bleed any air in the calorifier, the

conduits or the taps to prevent the annoying noises likely to

be produced during heating or when tapping water.

The water is circulating too

quickly in the central heating

system.

Contact the fitter.

Significant water leak under or

close to the boiler

The boiler or central heating pipes

are damaged.

Close the water supply. Contact the fitter.

MCR 24/28 BIC

6. Troubleshooting

170513 - 300024112-001-01