DE DIETRICH 200 SSL User Manual

Page 10

Advertising
background image

DHW tank 200SSL
Maximum operating temperature

°C

95

Maximum operating pressure

bar (MPa) 10 (1.0)

Water content

l

200

Top up volume

l

90

Solar volume

l

110

Weight
Shipping weight (Foam coated domestic hot water tank) kg

112

Performances related to the boiler type

Gas fired floor-standing condensing boiler

(1)

17/29 kW

25 kW

Power exchanged

kW

24

24

Flow per hour (∆T = 35°C)

(2)

l/h

590

590

Specific flow (∆T = 30°C)

(3)

l/min

18

18

Draw-off capacity

(3)

l/10 mm

180

180

Q

p

: Primary flow rate

m

3

/h

1.1

1.1

(1) Depending on the country in which the boiler is installed

(2) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary circuit (heating water): 80 °C

(3) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Primary circuit (heating water): 80 °C - Calorifier temperature: 60 °C

3.3

Composition of the NF CESI solar systems packages (for France only)

Check the composition of the NF CESI solar system package against

the table below. The references and packages listed must be shown

on the invoice for the system sold by the installer.

A system is complete and functional according to the NF CESI mark

if all system references appear on the invoice. The system is

composed of the following elements:

4

A collector field with 1 or 2 solar collectors.

4

A boiler system (Twineo or OEnoviaGas) + solar domestic hot

water tank to which a solar station is mounted in the factory, which

includes a heating pump, an expansion vessel and a Diemasol A /

Oetrosol A control system.

4

The solar fluid that protects the installation from frost and

corrosion.

CESI System

Array of collectors

Domestic hot water production

Solar fluid

Type of mounting package /

Reference

Boiler + DHW tank package package / Reference package /

Reference

INISOL Twineo
200-2

(1 collector)

On roof

ER152
100014074

200 SSL
EGC 25 VH / V200SSL
EGC 25 VH / B200SSL
EGC 25 VV / V200SSL
EGC 25 VV / B200SSL
EGC 17-29 VH/V200SSL
EGC 17-29 VH/B200SSL
EGC 17-29 VV/V200SSL
EGC 17-29 VV/B200SSL

ER221-100016426
100018141
100018143
100018142
100018144
100018141
100018143
100018142
100018144

EG101
89807794

Roof-integral

Installation (> 20°)

ER153
100014075

Roof-integral

Installation (17°)

ER230
100014740

3. Description

200 SSL

9

01/08/2013 - 300028225-001-02

Advertising