Checking and maintenance, General instructions, Cleaning the casing material – DE DIETRICH 200 SSL User Manual

Page 14: Sacrificial anode, Inspection and maintenance of the solar circuit, 5 checking and maintenance, 1 general instructions, 3 cleaning the casing material, 4 sacrificial anode, 5 inspection and maintenance of the solar circuit

Advertising
background image

5 Checking and maintenance

5.1

General instructions

CAUTION

4

Maintenance operations must be done by a qualified

engineer.

4

Only original spare parts must be used.

5.2

Safety valve or safety unit (Domestic hot water circuit)

The valve or safety assembly must be operated at least once a
month

in order to ensure that it is operating correctly and to prevent

possible overpressure which would damage the DHW tank.

WARNING

Failure to comply with this maintenance rule may cause

deterioration of the DHW tank and the cancellation of the

guarantee.

WARNING

Only operate the valve (red head) on the DHW circuit. Do

not operate the valve (yellow head) on the solar circuit.

5.3

Cleaning the casing material

Clean the outside of appliances using a damp cloth and a mild

detergent.

5.4

Sacrificial anode

Have the condition of the anode checked after the first year. The

magnesium anode must be checked by a qualified professional at

least every 2 years.

5.5

Inspection and maintenance of the solar circuit

We recommend that you take out a maintenance contract

providing for an annual or biannual check of the fluid level,

the antifreeze protection, the pressure of the installation

and the expansion vessel, its tightness and its general

running.

5. Checking and maintenance

200 SSL

13

01/08/2013 - 300028225-001-02

Advertising