15/09/2008 - 300008541-001-E

CBB

6. Stopping the boiler

6 Stopping the boiler

1. Wait until the logs have stopped burning (Wait 3-4 hours).

2. Set the On/Off switch to 0.

Specific precautions

Outside the heating period:
- Turn on the circulating pumps at least 1 time per month for 2

minutes.

- Thoroughly clean the heating surfaces in the boiler.

Precautions to take if there is a danger of frost

Heating circuit:
Use a correctly dosed antifreeze to prevent the heating water
freezing. If this cannot be done, drain the system completely. In all
cases, consult the fitter.
Domestic hot water circuit:
Drain the domestic water tank and pipes.

Precautions to take in the event of prolonged
shutdown (one year or more)

- The boiler and the chimney must be swept carefully.
- Close the door of the boiler to prevent the internal circulation of air.