Troubleshooting, Anti-hunting, Messages – DE DIETRICH MIT iSystem User Manual

Page 24: 5 troubleshooting, 1 anti-hunting, 2 messages

Advertising
background image

5 Troubleshooting

5.1

Anti-hunting

When the heat pump is in "anti-short cycle" operating mode, the

symbol "?" flashes. This is a normal operating mode. When the restart

temperature is reached, operation will be guaranteed.
1. Press the "?" key.

The message Operation assured when the restart temperature
will be reached

is displayed. When the restart temperature is

reached, operation will be guaranteed.

This message is not an error message but an item of

information.

5.2

Messages

In the case of failure, the control panel displays a message and a

corresponding code.
1. Make a note of the code displayed.

The code is important for the correct and rapid diagnosis of the

type of failure and for any technical assistance that may be

needed.

2. Switch off heat pump and start up again.

The heat pump starts up again autonomously when the cause of

the failure has been lifted.

3. If the code is displayed again, correct the problem by following the

instructions in the table below:

Code Messages

Description

Checking / solution

B0

BL.PARAM.CRC

Error parameters.

4

Switch off the mains supply to the installation

4

Switch back on

B1

BL.NO CONFIG

The inside module has not been

configured.

The PSU PCB has been changed.

4

Contact the professional who takes care of maintenance

of the appliance.

B2

BL.MIT/MHR S.

The MIT flow sensor is short

circuited or on an open circuit.

Bad connection.

4

Contact the professional who takes care of maintenance

of the appliance.

B3

BL.S.DEP.HP

Heat pump flow sensor error.

Bad connection.

4

Contact the professional who takes care of maintenance

of the appliance.

B4

BL.S.EXT.HP

Source sensor error/heat pump

outside temperature sensor.

Bad connection.

4

Contact the professional who takes care of maintenance

of the appliance.

B5

BL.S.RET.HP

Heat pump return sensor error.

Bad connection.

4

Contact the professional who takes care of maintenance

of the appliance.

5. Troubleshooting

MIT iSystem

23

24/05/2012 - 300028952-001-01

Advertising