Page 14: 4 operating the appliance, 1 reading out measured values

Advertising
background image

4 Operating the appliance

4.1

Reading out measured values

Scroll down the values measured using the ( and ) keys.

Parameter Description

Remarks

TC

Collector temperature S1 sensor.

The value TC shows the temperature in °C given by the collector sensor in real time.

TR

Calorifier temperature

(Solar exchanger -

lower)

S2 sensor.
The value TR shows the temperature in °C in real time measured by the sensor in the lower

zone of the DHW calorifier.

THR

Calorifier temperature

(Back-up)

S3 sensor.
The value THR shows the temperature in °C in real time measured by the sensor in the

upper zone of the DHW tank.

PC %

Pump regime

Value PC % gives the solar heating pump regime in real time (0-100%).

tc

Auto-calibration time

The value tc shows the self-calibration phase time remaining in seconds.

RAP

Force back-up

On

: Back-up powered up.

AUTO

: Back-up managed by the control system.

¼See chapter: "Force back-up", page 14.

h P1

Hour run meter on the

solar pump

Reset to zero possible.

¼See chapter: "Resetting the values to zero", page 13.

KWh

Amount of heat (kWh) 4

The amount of heat received is calculated according to the parameters input on

commissioning (DMAX).

4

Reset to zero possible.

¼See chapter: "Resetting the values to zero", page 13.

Values KWh or MWh give an estimate of the total amount of heat produced by the

installation in kWh or MWh since commissioning of the control system. The amount of heat

received is calculated according to the parameters input on commissioning (DMAX).

MWh

Amount of heat

(MWh)

HRE

Time

¼See chapter: "Setting the time", page 14.

4.1.1.

Resetting the values to zero

It is possible to reset the value to zero when the symbol T is

displayed.
1. Select a value using the ( and ) keys.
2. Press the B key for 2 seconds. The value is reset to zero.

To suspend the operation, do not press any keys for 5

seconds. The control system will automatically go back to

the value display mode.

4. Operating the appliance

BSL 150...400 BESL 200...400

13