5. CVBS Out

When CVBS_Out open, cameras support analogue BNC output, the default is CLOSED.

6. Auto Iris

1).when IrisMode off, Iris open max always. When IrisMode on, Iris will work after the priority of shutter.

2).Voltage: Voltage is different for different iris. The recommended value is 64 ± 8 micro. If the voltage is

too low, image will be dark even flashing while too high, image will be overexposure

3) IrisOpenSpeed and IrisCloseSpeed: the speed of iris change, when image flash and it is no use by

adjusting voltage, adjust the IrisSpeed, the recommended speed value for IrisOpenSpeed is 52, and

IrisiCloseSpeed is 94.