2 cylinder details – FlexLink X65 Функциональные модули Руководство пользователя User Manual
Page 30
Advertising

22
8050179
Functions
3.3.2
Cylinder details
Cylinder A1 and A2 "Pre-stop"
Type: Single acting with two ports.
Function:
• Pressurized: Releases the pallet flow
• No pressure: Blocks the pallet flow
It is recommended to re-block the flow after each
pallet.
Cylinder A3 "Arm"
Function: Change the flow through the module.
For safety reasons, the pallet stop is blocking the
flow in case of a pressure drop, preventing pallets
from travelling uncontrolled along the conveyor.
The stop should not re-block the flow while a pallet
puck is in a position where it could be clamped.
Type: Double acting
Cylinder A1 and A2
Cylinder A3
Advertising