Installation and adjustment
54
5112204
Interlocking sensors
The light beam of the photo-electric sensor should hit the reflector. The lift
cage should not act as obstacle at any height.
5.5.6.2.2
Adjustment
The sensor is adjusted so that the XT conveyers stops within the area, lim-
ited by the two photo-electric laser cells (WL9L).
5.5.6.3
Limit switches
This does not apply to RTI units. These should be protected by the appli-
cation.
Figure 30 Limit switches
The limit switches are located in the upper and lower parts of the frame and
are activated in the event of excessive lifting device travel.
Mechanical dampers serve as protection after the limit switches.
To assure correct operation of the elevator, ensure that the switches are
correctly positioned and are activated in the intended direction of travel.