C-4 Command Operation

C-4-1 General Commands

These commands are general basic utility types.

C-4-1-1 Command Synchronize

This command string terminates commands that may be presently in
process and resets the command state machine operation to the initial
ready state. It can be sent to instruments in a network to provide command
state machine synchronization.

HOST SEND

<esc>AZ<cr>

RESPONSE - none

C-4-1-2 Menu Command

This command is provided for terminal-oriented use and causes display of
a menu listing the basic available command arguments, make, model,
code version, and object code start vector. The menu does not include
special factory diagnostic and production test commands.

HOST SEND

AZM<cr>

Non-network

AZ[yyyyy]M<cr>

Network

RESPONSE

<cr><lf><lf><lf><lf><lf><lf><lf><lf><lf><lf><lf><lf><lf><lf><lf><lf>

Brooks Instruments

COMMANDS - Model 0254 V01.03.21 FD00

<cr><lf><lf>

[M] Command Select Menu<cr><lf>

[V] Display Port Values<cr><lf>

[K] Send Measured<cr><lf>

[I] Product Identify<cr><lf>

[P] Program New Values<cr><lf>

[Z] Clear Measured Values<cr><lf>

[F] Batch Control Service<cr><lf>

[B] Blend Control Service

[G] Log Record Service