Assembly

8.3.2. installing the actuator (welded body)

Graphite seal

Fig. 20: Graphite seal

→

Check graphite seal and, if required, replace. Remove all
residues when replacing seal.

Warning!

danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen
applications there is a risk of an explosion!
• In specific applications, e.g. oxygen or analysis applications, use

appropriately authorized lubricants only.

→

Grease nipple thread before re-installing the actuator
(e.g. with Klüber paste UH1 96-402 from Klüber).

note!

damage to the seal on the swivel plate!
• When installing the actuator, ensure that the valve is in the open

position.

→

Control function A and I:
Pressurize lower control air connection with compressed air
(5 bar) so that the swivel plate is lifted off the valve seat and is
not damaged when screwed in.

→

Screw actuator into the valve body.

tightening torques:

Orifice

(dn)

tightening torque

(nm)

15

45 ± 3

20

50 ± 3

25

60 ± 3

32

65 ± 3

40

65 ± 3

50

70 ± 3

65

70 ± 3

Tab. 10: Tightening torques

If the body is stainless steel, grease the nipple thread with
e.g. Klüber paste UH1 96-402.