Basicsafetyinstructions

3.1.6. adhesive label for ex area

ii 2g c iic t4

ii 2d c t135°c

Warning: not valid when non-ex devices added
Warning: potential electrostatic charging hazard

-see instructions

Fig. 1: Label Ex area

3.1.7. temperature ranges in the ex area

max. t

environment

medium

<

– dn 25

> dn 25

T6 85 °C

-10 ... +45 °C

-10 ... +55 °C

T5 100 °C

-10 ... +60 °C

-10 ... +70 °C

T4 135 °C

-10 ... +95 °C

-10 ... +105 °C

Tab. 1: Temperature ranges Ex area

10

20

30

40

50

60

70

80

90

100 110 120 130

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

Temperature class T6

Temperature class T5

Temperature class T4

Medium temperature [°C]

Ambient

temperature

[°C]

Valves
<

– DN 25

Valves
> DN 25

Fig. 2: Temperature ranges Ex area

3.2.

special conditions

To ensure potential equalization, ground the valve body to the pipe
system using an electrically conductive connection.

For use in Ex area zone (gas) 1 and 2,

zone (dust) 21 and 22, applies:

Danger!

danger of explosion caused by electrostatic charge!
In the event of a sudden discharge from electrostatically charged
devices or individuals there is a risk of an explosion in the Ex area.
• Implement suitable measures to ensure that there are no elec-

trostatically charges in the Ex area.

• Only clean the surface of the device by gently wiping with a

damp or anti-static cloth.

Follow instructions for use in the Ex area! See chapter “3.1”.