Assembly

stainless steel insert (only for units without diaphragm and
casing):
A VA insert (order no. 648 864) is enclosed with a device which is
supplied without a diaphragm and body.

use of an epdm / Fkm diaphragm:

→

When installing a device with elas-
tomer diaphragm (EPDM / FKM),
insert the VA insert into the groove
of the pressure piece.

use of a ptFe - diaphragm:

→

When using a PTFE diaphragm,
the insert is not required.

insert

6.3.2 connection of the control medium

control function a:

→

Connect control medium to lower connection.

control function b:

→

Connect control medium to upper connection.

control function i:

→

Connect control medium to upper and lower connections
(see „Fig. 7: Control air connection“).

→

Pressure on the upper connection closes the valve.

→

Pressure on the lower connection opens the valve.

6.4 maintenance work

6.4.1 actuator

The actuator of the diaphragm valve is maintenance-free provided it is
used according to these operating instructions.

6.4.2 Wearing parts of the diaphragm valve

Parts which are subject to natural wear:
• Seals

• Diaphragm

→

If leaks occur, replace the particular wearing part with an appro-

priate spare part.

For the maintenance and repair instructions see operating
instructions (DN65 - DN100) on the Internet at:

www.burkert.com

A distended PTFE diaphragm may reduce the flow-rate.

6.4.3 inspection intervals

→

Check diaphragm for wear after a maximum 10

5

switching

operations.

Muddy and abrasive media require correspondingly shorter
inspection intervals!