Burkert Type 2037 User Manual

Page 9

Advertising
background image

9

Assembly

6.2.1 installation position general

installation for self-drainage of the body

It is the responsibility of the installer and operator to ensure
self-drainage.

installation for leakage detection

One of the bores (in the actuator base) for monitoring
leakage must be at the lowest point.

6.2.2 installation position 2/2-way valve

• The piston-controlled diaphragm valve can be installed in any

position, preferably with the actuator face up.

To ensure self-drainage:

→

Install body at an angle α = 10° to 40° to the horizontal
(see „Fig. 2“).

→

Maintain an inclination of 1° – 5°.

There is a mark on forged and cast bodies, which must face

upwards (12 o’clock position, see „Fig. 3“).

→

One of the bores (in the actuator base) for monitoring leakage,

must be at the lowest point.

α

Angle α: 10° to 40°
Inclination to the line axis 1° ... 5°

Fig. 2:

Installation position for self-drainage of the body

Marking for self-draining
inclination

Fig. 3:

Mark for correct installation position

english

Type 2030, 2031, 2031 K, 2032,

2033, 2037