Burkert Type 3236 User Manual

Page 39

Advertising
background image

39

Repairs

Type 2035 / 3236

Guide bolt

12

45°

Diaphragm

Pressure pieces

11

10

8

6

Spacer sleeve

7

Actuator spindles

Pressure pieces

Diaphragm

9

Fig. 33: Assembly of the RV110 pneumatic actuator

test for leak-tightness / valve function

Warning!

danger of injury through egress of flow medium.

▶ Tighten the body screws / nuts sufficiently.

Applying an unnecessary degree of force to tighten the
body screws / nuts leads to increased wear and therefore
shortens the service life of the diaphragm.

If the valve leaks when the medium pressure rises:

→

Tighten the diagonally opposed body screws / nuts by a one-
eighth turn until the valve no longer leaks.

This procedure ensures that the diaphragm and the pressure piece
are optimally aligned to each other and the valve function is ensured.

→

Switch the valve several times and if necessary tighten the body
screws / nuts more.

english

Advertising
This manual is related to the following products: