Installation

1

2

Pilot air port

CFA, CFB, CFI

Air discharge connection CFA, CFB

and second pilot air port CFI

Fig. 38: Pneumatic connection

control air hose:
Control air hoses of sizes 6/4 mm or 1/4“ can be used.
Optionally a pilot air port is possible via a G 1/8 thread.

8.5

removal

Danger!

risk of injury from discharge of medium and pressure!
It is dangerous to remove a product which is under pressure due
to the sudden release of pressure or discharge of medium.

▶ Before removing a product, switch off the pressure and vent the

lines.

procedure:

→

Loosen the pneumatic connection.

→

Remove the product.

Replacement of the diaphragm is described in the chapter
entitled “11 Repairs”.