Technical data – Burkert Type 6608 User Manual

Page 4

Advertising
background image

12

7. Technical daTa

Operating conditions

7.1.

Warning!

Risk of injury
Malfunction if used outside!

Do not use Type 6128 and Type 6608 outdoors and avoid

•

heat sources which may cause the allowable temperature

range to be exceeded.

Allowable temperatures
Ambient temperature

0 - +60 °C

Medium temperature

0 - +70 °C

Media

neutral and aggressive, gaseous and
liquid media which do not attack body
and seal materials
see Buerkert Chemical Resistance Chart
(

www.burkert.com

)

Protection class IP40

english

13

conformity

7.2.

CE mark conforms to EMC Directive 2004/108/EC
(only if cables, plugs and sockets connected correctly).

mechanical data

7.3.

Dimensions

See data sheet

Body material

Type 6128:

PPS,

Type 6608:

PEEK

Seal material

Type 6128:

FKM, EPDM

Type 6608:

FFKM

FKM and EPDM on

request

english

13

14

7.4. pneumatic data

Circuit functions (CF)

A

A

P/NC

2/2-way valve, direct-acting,
normally closed

B

B

P/NO

2/2-way valve, direct-acting,
normally open

C

A in/out

P/NC R/NO

3/2-way valve, direct-acting,
normal output A unloaded

D

B in/out

P/NO R/NC

3/2-way valve, direct-acting,
normal output B pressurized

T

A in/out

P/NC R/NO

3/2-way valve, direct-acting,
universal function

english

15

Note the information specified on the label for
voltage, type of current, and pressure.

Pressure range

Vac - 10 bar

Port connections

Threaded connection G1/8 or
NPT1/8

Flange connection

english

15

Type 6128, 6608

Advertising
This manual is related to the following products: