24

note!

If the tightening torque is too great, the device may
be damaged!

Observe the maximum tightening torque of the screws!

•

Attach valve to manifold:

→

Screw in screws at 0.8 Nm.

Tightening torque
0,8 Nm

Attach coil to body.

→

english

25

Danger!

Risk of electric shock if the protective conductor
function is defective!

After installing the coil, check the function of the pro-

•

tective conductor (see chapter entitled “

8.3. Electrical

Installation”).

Dimensional drawing for manifold:

27

18

M3 min. 6 deep

13.5

max. ∅4

NC IN/OUT NO

18

45.5

44

max. ∅4

M3 min. 6 deep

11

M4 min. 6 deep

Flange layout for
manifold mounting

Flange layout for
single mounting
with clamp

english

25

26

Arrangement of the bores:

3-way

2-way

english

27

8.3. electrical installation

Danger!

Risk of injury due to electrical shock!

Before reaching into the device or the equipment,

•

switch

off the power supply and secure to prevent reactivation!
Observe applicable accident prevention and safety

•

regulations for electrical equipment!

Types of electrical connections:

Rectangular
plug

Flying leads

Circular plug

Connection above

english

27

Type 6128, 6608