background image

12

Configuration and Function

7.

CONFIGURATION AND FUNCTION

7.1.

Operating and Display Elements

7.1.1.

Operating unit

The operating unit consists of a LCD and keys. It is used for displays and settings of the Control Electronics, Type
8605.

Unit of the displayed value
(s, Hz, %, mA, V)

LCD

Lower limit

= active

= not active

Setpoint = Setpoint
(of the coil current)

Process value = Actual value
(of the coil current)

Upper limit

Figure 3:

Operating unit

Key assignment:

Key

Display mode

Configuration

mode

Selected and confirmed menu item

Switch over the display
value

PV [mA] process value
PV [%] process value
SP [%] setpoint
TV [%] duty cycle

Scroll up
(selection)

Increment (increase)
numerical values

Scroll down
(selection)

Decrement (decrease)
numerical values

3 sec
Enter configuration mode

Confirm the
selected menu item

Select and deselect the individual menu
items

Switch between
main-menu and
sub-menu items
e. g.: Out-VALV

Confirm set values