Electrical installation

9.1.1. adjustment of the proximity

switches

DangEr!

risk of electric shock!
• Before reaching into the system, switch off the power supply

and secure to prevent reactivation!

• Observe applicable accident prevention and safety regulations

for electrical equipment!

Screw for adjustment of the upper
proximity switch

Screw for adjustment of the lower

proximity switch

adjustment of the prox-
imity switches
upwards

downwards

turn screw
clockwise

turn screw
anticlockwise

Fig. 20: Adjustment of the proximity switches

procedure:

→

Open the Pneumatic Control Unit: unscrewing the transparent
cap in an anticlockwise direction.

→

Adjust the the proximity switches via the adjusting screw(s) (see
“Fig. 20”).

→

Check the switching point(s) using suitable measuring
equipment.

→

Check that the seal is correctly positioned in the transparent cap
(see “Fig. 21”).

Seal
transparent cap

Transparent
cap

Fig. 21: Position of the seal in the transparent cap

noTE!

damage or malfunction due to penetration of dirt and
humidity!
• To observe protection class IP65 / IP67, screw the transparent

cap in all the way.

→

Close the transparent cap (assembly tool: 674077

6)

).

6)

The assembly tool (674077) is available from your Bürkert sales
office.