Disassembly

13.2. Disassembly the pneumatic

control unit

procedure:
1. Pneumatic connection

DangEr!

risk of injury from high pressure!
• Before dismounting lines and valves, turn off the pressure and

vent the lines.

→

Loosen the pneumatic connection.

→

Series 20xx:
Loosen the pneumatic connection between Pneumatic Control
Unit and actuator.

2. Electrical connection

DangEr!

risk of electric shock!
• Before reaching into the system, switch off the power supply

and secure to prevent reactivation!

• Observe applicable accident prevention and safety regulations

for electrical equipment!

Circular plug-in connector:

→

Loosen the circular connector.

Cable gland:

→

Open the Pneumatic Control Unit: unscrewing the transparent
cap in an anticlockwise direction.

→

Unscrew the screw terminals and pull out cables.

3. Mechanical connection

→

Loosen the fastening screws.

→

Remove the Pneumatic Control Unit upwards.

Pneumatic

Control Unit

Transparent cap

Fastening screws

(2x)

Pneumatic

connections

Pneumatic con-

nection to the

actuator

Actuator

Cable gland

Series 21xx

Series 20xx

Fig. 23: Disassembly the Pneumatic Control Unit