61

Disassembly

2. Electrical connection

Danger!

risk of electric shock.

▶ Before working on equipment or device, switch off the power supply and secure to prevent reactivation.

▶ Observe applicable accident prevention and safety regulations for electrical equipment.

Circular plug-in connector:

→

Loosen the circular connector.

Cable gland:

→

Open the control head: unscrewing the transparent cap in an anticlockwise direction.

→

Unscrew the screw terminals and pull out cables.

→

Close the control head.

3. Mechanical connection

→

Loosen the fastening screws.

→

Remove the control head upwards.

Pneumatic
connections

Control head

Actuator

Fastening

screws (2x)

Pneumatic con-

nection to the

actuator

Actuator

Electrical

connection

circular plug-in

connector

Series 21xx

Series 20xx

Figure 49:

Disassembly the control head