Burkert Type 8645 User Manual

Page 10

Advertising
background image

10

EXPANDING A VALVE TERMINAL

Step 8:

Push the blue locking bracket over the desig-

→

nated guides.

Ensure that the connecting bracket is inserted neatly
into the guides and is pushed down parallel.

To do this, support the bracket by gripping both

→

lugs.

Attaching the connecting bracket

Fig. 10:

Step 9:

If more modules are to be added, repeat steps

→

5 – 8.

In doing so, note the appropriate system limits. To
close the valve terminal, attach the cover module
which fits the corresponding head module.

Attach cover module by pressing parallel on the

→

valve terminal.

Ensure that O-rings, seals and electrical interface are
not damaged.

Attaching more modules

Fig. 11:

Schritt 10:

Lock locking pins according to Step 7 and push

→

down blue connecting bracket according to Step
8.

Re-attach FE rails.

→

Connect additional modules accordingly to the

→

FE contact.

Attaching the connecting bracket

Fig. 12:

Step 11:

The valve terminal is ready for use again!

Valve terminal ready for use

Fig. 13:

english

Type 8645

Advertising