EXPANDING A VALVE TERMINAL

Step 5:

Before adding new modules, first check that the

O-rings and seals are correctly positioned.

Then grease the O-rings and seals, both on

the pneumatic channels and on the electrical
connections.

Checking O-rings and seals

Fig. 7:

Step 6:

Connect additional module to the valve terminal

by pushing it on parallel and pressing it into
position.

Ensure that the seals and plug-in contacts are not
damaged.

Attaching additional module

Fig. 8:

Step 7:

Connect added modules to the existing valve

terminal by pressing and then turning the three
locking pins clockwise through 90°.

The depression of the locking pins can be facili-

tated by pressing the module onto the existing
valve terminal. The slot is vertical.

Then attach the added modules to the wall or top

hat rail.

Securing added modules

Fig. 9: