Burkert Type 1094 User Manual
Page 2

2
Information on the replacement
of the electronic control
Pin assignment for replacement of the ident. no. 191675
GND
Diesel 2
GND
Impuls 2
GND
Diesel 1
GND
Impuls 1
+ Input
Frequency input
Gasoline pulse
Side 1
GND
+ Input
Diesel identifier
Side 1
GND
+ Input
Frequency input
Gasoline pulse
Side 2
GND
+ Input
Diesel identifier
Side 2
GND
Assignment of inputs
out
+
–
+
–
in
in
15 V
Eingang 2
Input 2
Eingang 1
Input 1
0 V
24 V
Pumpe 1 out
out
Pumpe 2 out
out
–
+
–
+
24 V
24 V
Ventil 1
Valve 1
Ventil 2
Valve 2
Old ident. no. 191675
is replaced by ident. no. 208373
Protective conductor
+ 24V
GND
+
–
+
–
+
–
+
–
Ventil 1
Schütz 1
Ventil 2
Schütz 2
GND
Motor contactor control
Side 2
+ Output
GND
Valve control
Side 2
+ Output
GND
Motor contactor control
Side 1
+ Output
GND
Valve control
Side 1
+ Output
GND
24 V supply
+ Output
Assignment of outputs
Overview of assignment: Old → New
Labeling
Pin assignment (old)
Labeling
Pin assignment (new)
Protective conductor
→
No longer available/required
15 V out
→
No longer available
Input 2
Input 2 and GND
→ Impuls 2 / GND Frequency input of gasoline pulse, side 2
Input 1
Input 1 and GND
→ Impuls 1 / GND Frequency input of gasoline pulse, side 1
0 V / 24 V in
Supply GND / 24 V DC
→ GND / + 24 V
24 V supply
Pumpe 1 / 24 V out Control of pump 1
→ Schütz 1
Control of motor contactor, side 1
Pumpe 2 / 24 V out Control of pump 2
→ Schütz 2
Control of motor contactor, side 2
Valve 1
Valve 1 (+ and –)
→ Ventil 1
Control of valve, side 1
Valve 2
Valve 2 (+ and –)
→ Ventil 2
Control of valve, side 2
also Diesel 1 / 2
Diesel identifier sides 1 and 2
english
Type 1094