Burkert Type 8076 User Manual

Page 19

Advertising
background image

19

Installation and wiring

Type 8026- 8036- 8076

Correct

Incorrect

Fig. 12: Air bubbles within the pipe / Filling of the pipe

→

Fit the display module (see related operating manual) to para-
meter the device.

→

Assemble the flowmeter 8036 (see „Fig. 13“) or install the flow-
meter 8026 into the fitting S020 (see „Fig. 14“)

SE36

S030

1

2

3

SE36

S070

1

2

→

1 : Insert the electronic module in the sensor holder.

→

2 : Turn the electronic module by a quarter turn.

→

3 : Secure the electronic module and the S030 fitting only, by
tightening the screw with a suitable tool to a max. tightening
torque of 1 Nm.

Fig. 13: Assembling the SE36 and the fitting S030 or S070

A

B

→

Check that there is a seal on the fitting
and that it is not damaged. Replace the
seal if necessary.

→

Place nut A on the fitting and insert
circlip B into the groove.

→

Carefully insert the device into the
fitting. If assembly is correct, the device
can no longer rotate on itself.

→

Secure the unit with nut A, tightening
only by hand.

Fig. 14: Installation of flowmeter 8026 into the fitting S020

→

Set the K factor parameter (see chap. „8.8.8“) or have it deter-
mined through a teach-in procedure.

English

Advertising
This manual is related to the following products: