BATCH FUNCTION.

For each formula you can
associate:


q Product quantity
q Product name
q Maximum time for

batch (safety time for
each formula)

After activating the batch
function from visualization

page at pages 47, proceed
as in the aside example.

























VISUALIZATION PAGE WITH BATCH FUNCTION ENABLE

PROGRAMMING BATCH

Programming formula n°

product Name

Batch in progress

Visualizations:

1) batch off: n° batch effected
2) batch on: decrease safety timer

3) programming: programming safety timer

indefinite if timer=0 timer disabled

Programming batch quantity

Visualization batched product

Input key code

Choose the formula number for associate

quantity batch (between 00 and 15)

Input quantity product for each batch

Input product name for batch (max 8 characters.)

Input maximum time for batch

If timer = 0, safety timer disabled max time set

= 6000 sec.
N.B. if to one output is assigned the function of

batch alarm, to the attainment of the maximum
time, beyond to the interruption of the batch,

will have activated also the alarm output

From the visualization pages

ENABLE BATCH
Enable one of the following functions to enable and program the batch on the converter:
q POS. 5.9-5.10: START/STOP batch from input
q POS. 6.1-6.2: assign one of the functions to one of two output

Some examples of operation of such functions are visualized from page 11