3 mounting of the panel-mounted version, English – Burkert Type 8032 User Manual
Page 14

ENGLISH
ENGLISH
remote flow rate controller 8032
4.3 mounting of the panel-mounted version
1� Cut away, according to one of the drilling jig hereafter, the opening in the panel (thickness
between 1 and 3 mm) of the switch cabinet� Make sure to scrupulously respect the indicated
dimensions�
47,2 ±0,2
47,2 ±0,2
45
45
=
=
=
=
∅ 3 (x4)
R3-7 (x4)
∅ 3 (x4)
47,2 ±0,2
=
=
48
45°
45°
45°
47,2 ±0,2
=
=
45°
61,6
2� On the rear face of the electronic board, disconnect the 5 wires [1] by pressing the orange
locking levers with a screwdriver, then pull out flat cable [2]�
3� Unfasten the 4 screws [3] on the front face [4]�
4� Set front face [4] with seal [5] onto the opening, the electronic board facing the inside of the
cabinet�
5� On the rear side of the device, connect flat cable [2] back by maintening the front face and
4
installation
Minimal opening
Maximal opening