LED on remote control not illuminating, or is

dim when unit is operated

1. Ensure battery is connected with correct polarity

2. Ensure battery connections are good

3. Replace

battery

PIR Detector false alarming

1. Ensure that the detector is not pointing at a

source of heat or a moving object

2. Ensure that the detector is not mounted above a

radiator or heater

3. Ensure that the detector is not facing a window

or in direct sunlight

4. Ensure that the detector is not in a draughty

area

5. Sensitivity detection set too high –reset to low

sensitivity detection

PIR Detector not detecting a person’s movement

1. Check battery connections are good.

2. Sensitivity detection set too low– reset to high

sensitivity detection.

3. Check that the detector is correctly set up.

4. Ensure DIP switches 1-2 of SW2 are correctly

set.

5. Ensure that detector is mounted the correct way

up.

(i.e. with detection window at the bottom)

6. Ensure that the detector is mounted at the

correct height, (i.e. 2-2.5m).

7. Allow up to three minutes for detector to

stabilize.

PIR Detector LED flashes on detection of

movement, (device in normal operation mode)

1. Low battery – replace battery.

Event & Schedule not working under disarm,

fully arm and partial arm

Set ‘Event & Schedule’ to on

Magnetic Contact Detector not working

1. Ensure batteries are connected with correct

polarity.

2. Ensure battery connections are good.
3. Ensure ‘Code Learning’ emitted to Control Unit

is correctly proceeded.

4. If no external contacts are connected ensure

correct setting is made on the DIP switch

5. If external contacts are connected

a. Check that all contacts are closed.
b. Check all contacts are wired in series.

Magnetic Contact Detector false alarming

1. Ensure that gap between magnet and detector

is less than 10mm.

2. Tamper switch below battery cover not

depressed – check battery cover is fitted
correctly and that fixing lugs are not broken.

LED on Magnetic Contact Detector illuminating
when door or window is opened.

1. Low battery – replace batteries.

DIGITAL DIALER TRANSMISSION
PROTOCOL

Contact ID Event Codes

Definition

Code

Fire/Smoke Alarm

110

Panic Alarm

120

Intruder Alarm

130

24hr Intruder

133

System Tamper

137

AC Failure

301

System Low Battery

302

Sensor Tamper

383

Sensor Low Battery

384

Cancel/Abort Alarm

406

System Test

601

Disarm(Open)/Arm(Close) by User

401

Periodic Test Report

602

Flood Alarm

113

Gas Alarm

151

A501111603R01