Test menu, English, Offset span signal t° adjust end simul reset – Burkert Type 8175 User Manual

Page 118

Advertising
background image

50

8175

ENGLISH

TEST MENU

4.5 TEST MENU

PRESS

0......9

ENTER

SIMULTANEOUSLY FOR 5 SECONDS

The following parameters are selected and set within this menu:

The following sections explain how to change and investigate the parameter values within
the test menu above.

0......9

OFFSET

SPAN

SIGNAL

T° ADJUST

END

SIMUL

RESET

Function

Section

Zero point compensation (4 mA).

4.5.1

Span compensation (20 mA).

4.5.2

Temperature correction +/- 15

°C .

4.5.3

Display of the returned signal strength.

4.5.4

Input of the level, volume or temperature to be si-
mulated. The current and relay outputs will react
according to this value.

4.5.5

Reset of the device to the factory settings and
resetting of the echo filtering table (see 4.4.5).

4.5.6

Return to the main menu and store the new para-
meters. If one of the two values for OFFSET and
SPAN is inappropriate, the device will automa-
tically return to the «OFFSET» parameter and new
values must be entered.

Advertising