Fluid Components International FS2000L User Manual

Fluid Components International Equipment

Advertising
background image

This page is subject to proprietary rights statement on last page

Quick Installation and Adjustment Overview

Section A - Instrument Description and Identification
Section B - Instrument Installation
Install the instrument on to the application in the orientation required. Take extra precaution not to damage the sensing elements/surface. If wiring

conduit is required, make sure there are no obstructions leading to the wiring ports. Check for leaks.
Section C - Instrument Wiring
Verify the power and output load requirements for the instrument and install the proper wire size for the application. Wiring to relays will require

knowledge of the alarm state and load circuit. Take extra precaution not to damage the control circuits.
Section D - Power Up, Functional Verification and Adjustment.
Before applying power to the instrument, inspect the installation workmanship. In most cases the instrument will detect a flow or level alarm with

the factory settings. If the instrument does not respond, responds slowly or the alarm responds opposite to the required indication, follow the adjust-

ment procedure in this section or go to Section E.
Section E - Maintenance and Troubleshooting
Section F - Approval Information

Section A - Instrument Description and Identification

Thoroughly understanding the capabilities of the NuTec instrument, and its intended use for your application, will make the installation much easier.

This installation guide describes the four NuTec models available.

LS2000
The model LS2000 is an insertion instrument capable of detecting liquid levels or product interfaces in a wide range of processes. The instrument

can be top or side mounted. The process connection choices are male ¼ inch NPT, ¾ inch NPT or 1-1/2 inch, 150 lb. Flange. See the installation

outline drawings on page 3 or 4 for the correct mounting dimensions.
FS2000
The model FS2000 is an insertion instrument capable of detecting flow / no-flow in a wide range of processes. The instrument can be top or side

mounted. The process connection choices are male ¼ inch NPT, ¾ inch NPT or 1-1/2 inch, 150 lb. flange. See the installation outline drawings on

page 3 or 4 for the correct mounting dimensions.
FS2000H
The model FS2000H is an insertion instrument capable of detecting flow/no-flow in a wide range of processes. This probe offers our highest range

for flow detection. This probe is not required to protrude into the process flow, but can be inserted even with the pipe inside diameter and still offer

extended flow ranges. The process connection is a 1” NPT male thread. See the installation outline drawings on pages 3 and 4 for the correct mount-

ing dimensions.
FS2000L
The model FS2000L is a non-intrusive, in-line instrument capable of monitoring the flow rate of a wide range of gas or liquid processes. The instru-

ment can be mounted vertically or horizontally. The process connection choices are male NPT, butt weld or sanitary flange. See the installation

outline drawings on page 3 or 4 for the correct mounting dimensions.

NuTec Series Flow & Level Monitoring Switch

Installation and Operation Guide

®

Advertising
This manual is related to the following products: