16

Figure 8


Changing the parameters

+V, -V
Turn the +V knob to change the +V value. Turn the –V knob to change the –V
value. The underscored digit will be changed and it will be displayed in white type
inside a black box indicating the active field.
Use the arrow keys to move the selection. If the cursor is moved outside of +V
field limits, the –V field will become active and vice versa. Selection of the active
field can be done in two ways:

•

Automatically, by turning the appropriate knob (+V or –V) or

•

Moving the cursor from one field to another.


Note: When +V or –V is modified by the user, the programmed voltages are
displayed for about 3 seconds.

Monitoring the output voltages

•

+V, -V and the 5V voltages are continuously measured. While +V, -V and
5V voltages are between the specified tolerance the corresponding LEDs
will light green.

•

The fixed 5V voltage measurement is displayed continuously on the
screen. If the output accuracy is out of the specified tolerance (± 200mV),
the corresponding LED will light red.

•

The +V and –V voltage measurements are continuously compared to the
programmed values. If the output accuracy is out of the specified
tolerance (± 100mV), the corresponding LED will light red.

6.5 Debounced pushbuttons

Front-panel controls
Figure 9 shows the Debounced pushbuttons controls on the front panel of the
trainer.

Advertising