Function relay diagram, Omplete, Ystem – Green Air Products MCC-1 User Manual

Page 3: Ontrol, Perate, Mcc-1, Duration of "on" time frequency of "on" time

Advertising
background image

Timed

Outlet

Timed

Outlet

CO

2

Outlet

OFF

Cycle
Timer

CO2

Timer

Photo Sensor

MCC-1

24 Hour Timer

G

REEN

A

IR

P

RODUCTS

AT M O S P H E R I C S Y S T E M S & C O N T R O L S

Cycle Timer

7m

15m

1

2

3

5

6

7

8

5s

10

23

3.5m

17

30

15

5

15

21

HOURS

MINUTES

Ferquency

Duration

10

20

30

40

50

60

70

80

90

100

110

10

20

30

40

50

60

70

80

90

100

110

MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 15A MAX

Thermostat

Humidistat

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

5

6

7

8

9

10

11

12

HF-1
Relay

HR-1
Relay

CDDS-1
Trigger

Exhaust
Outlet

Cycle

Timer

Exhaust On
Temperature High
Humidity High
Timed Outlet
CO

2

Outlet

Cycle Outlet
Heater Relay
Humidifing Relay

H

OW

T

O

O

PERATE

Use Green Air Products function relays in combination with the MCC-1 to
operate high voltage or high amperage equipment. The MCC-1 outlets trigger
the relay contactor to close which switches power to the auxiliary equipment.
This design protects the controller from power overload and provides precise
and dependable system management. See detailed descriptions of function
relays.

C

OMPLETE

S

YSTEM

C

ONTROL

Function Relay Diagram

CO2 Equipment

110 V

Outlet

Exhaust/Intake

Fans

Digital Setpoint

Controller

Infrared CO2

Sensor CDM-1

Pumps, Solenoid

Valves or Irrigation

Controls

Lighting

240 V

Outlet

240 V

Outlet

Heating

Relay

240 V

Outlet

240 V

Outlet

High Amperage

Relay

High Amperage

Relay

110 V

Outlet

Humidifying

Relay

CDDS-1

Photo "Off" Light

CO

2

Off Outlet

M A N U FA C T U R E D B Y G R E E N A I R P R O D U C T S , U S A 11 0 VA C 1 0 A M A X

CO2 Equipment

ON

5s

23

3.5m

17

30

15

5

15

21

7m

15m

1

2

5

6

7

8

10

3

Exhaust On
Temperature High
Humidity High
Timed Outlet
CO2 Outlet
Cycle Outlet
Heater Relay
Humidifing Relay

Climate Controller

Thermostat

Humidistat

Sequence Timer

Exhaust
Outlet

HF-1
Relay

HR-1
Relay

CDDS-1
Trigger

On Timed

Outlet

Off Timed

Outlet

CO

2

Outlet

Cycle
Timer

Outlet

DURATION

Of "ON" Time

FREQUENCY

Of "ON" Time

24 Hour Timer

OFF

Photo Sensor

Cycle
Timer

CO2

Timer

AT M O S P H E R I C S Y S T E M S & C O N T R O L S

G

REEN

A

IR

P

RODUCTS

MCC-1

MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 15A MAX

CDDS-1

Photo "Off" Light

CO

2

Off Outlet

M A N U FA C T U R E D B Y G R E E N A I R P R O D U C T S , U S A 11 0 VA C 1 0 A M A X

CO2 Equipment

ON

Carbon Dioxide Digital Sequencer

G

REEN

A

IR

P

RODUCTS

AT M O S P H E R I C S Y S T E M S & C O N T R O L S

G R E E N A I R P R O D U C T S I N C .

G R E E N C O 2 " O N " .

C O 2 " O F F " .

R E D

DIGITAL EVENT

SEQUENCER

[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]

A
B
N / A
N / A
-
-
-
-
-
-

5 0 p p m
1 0 0 p p m
2 0 0 p p m
4 0 0 p p m
8 0 0 p p m
1 6 0 0 p p m

HYSTERESIS

PROGRAMMING

A B ppm

50
150
200
300

OFF
ON
OFF
ON

OFF
OFF
ON
ON

ON

OFF

476

CDMC-2

G

REEN

A

IR

P

RODUCTS

20

20

ON

OFF

30

40

40

50

60

60

70

70

80

80

AT M O S P H E R I C S Y S T E M S & C O N T R O L S

G

REEN

A

IR

P

RODUCTS

Humidistat

Humidifying Relay

HF-1

Atmospheric Controller

AT M O S P H E R I C S Y S T E M S & C O N T R O L S

G

REEN

A

IR

P

RODUCTS

HAR-1

High Amperage Relay

AT M O S P H E R I C S Y S T E M S & C O N T R O L S

G

REEN

A

IR

P

RODUCTS

HAR-1

High Amperage Relay

20

ON

OFF

OFF

30

40

50

60

70

80

GREEN AIR PRODUCTS

AT M O S P H E R I C S Y S T E M S & C O N T R O L S

HR-1

Heating Relay

Thermostat

HEATER

HUMIDIFIER

The MCC-1 was designed to be used independently or in conjunction with Green Air Products
function relays. The MCC-1 will serve independently for systems and equipment requiring 115
VAC of 12Amps or less. Plug power cord into surge protected outlet and locate controller
where good air circulation represents plant zone conditions. Plug exhaust fan into exhaust
outlet. Set thermostat and humidistat dials to maximum desired values. Fan will operate
when conditions exceed those set points. Function indicator lights will display the
condition and outlet status. CO

2

equipment can be operated from the CDDS-1 trigger when

using the CDMC infrared monitor controller. This outlet provides an exhaust synchronized
override feature to delay enrichment during ventilation periods. When timed control is
desired plug CO

2

equipment into

CO

2

outlet and set timer mode toggle switch accordingly.

Set the sequence timer duration dial for minutes of "On" time and frequency dial for the
time between "On" functions. Exhaust demand will override CO

2

production and timer will

reset to cycle immediately following ventilation. CO

2

outlet is defeated by a built-in photo

sensor to operate only when light is present. If not being used for CO

2

enrichment the

sequence timer can be used for a variety of other timing duties. Switch the mode toggle to
"Cycle Timer" to bypass the exhaust and photoperiod defeat circuits. Timer "On" times
as short as 5 sec. can be achieved to operate irrigation pumps or solenoids for all kinds of
hydroponic and automatic watering systems. Plug thermostatically controlled heater into
HR-1 relay trigger outlet. Exhaust operations will override heating trigger to defeat heaters.
Use the HR-1 relay outlet for humidifiers to provide a comfort zone between humidifying
and dehumidifying. The 24 hour clock timer is useful for all daily oriented timing
operations. The 96 independent 15 min trippers allow any combination of on/off
functions repeated each 24 hours. Lighting, fans, pumps and watering are only a few of
the tasks this timer can perform. If your combined amperage draw exceeds 15 amp power
handling capacity of the controller optional high amperage function relays can be used to
provide service to large systems. Approved for indoor use only.