Do not inflate air springs over 50 psi – Hellwig Air 6110 User Manual
Page 3
Advertising

3. Install fitting in port of air spring. Torque fitting to approximately 20 ft-lb.
2. Install frame adapter on frame using M10-1.5 flat head cap screw. Align bracket
so that the inboard holes are evenly spaced from the inside wall of the frame rail.
Torque to 25 ft-lb.
559-734-7451 800-367-5480 FAX 559-734-7460
M10-1.5 Flat head cap
screw. Torque to 25 ft-lb
4. Install threaded studs into
frame adapter with countersunk
holes oriented as shown. Apply
loc-tite supplied in kit to threaded
studs before installation.
3/8” X 1-1/2” threaded stud
3/8” X 1” threaded stud
4
6110( R-6110)
DO NOT INFLATE AIR SPRINGS OVER 50 PSI
01/24/2013
Advertising