Indicator lights, Buttons, Display – Aquacal 35 EN User Manual

Page 4

Advertising
background image

Page 3

SECTION 3 - OPERATION

Figure 4

INDICATOR LIGHTS

LIGHTS

EXPLANATION

SUPPLEMENTAL INFORMATION

“Pool”

Pool Thermostat Selected

“Spa”

Spa Thermostat Selected

“Cooling”

Actively Cooling Water

Not applicable for Straight Heat models.

“Desired Temp”

Setting Desired Water Temperature

“Water Temp”

Actual Water Temperature

“Heating”

Actively Heating Water

Table 3

BUTTONS

BUTTONS

EXPLANATION

SUPPLEMENTAL INFORMATION

“Pool / Spa”

Select between Pool and Spa

Please note

– this does not turn off equipment. It only allows a user to

toggle between the Pool thermostat and the Spa thermostat.

“Up”

Select to raise temperature set
point or move up in a menu choice

“Down”

Select to lower temperature set
point or move down in a menu
choice

“Mode”

Select a mode

Modes available are “ACH”, “COOL”, “HEAT”, and “OFF”.
Please note

– “ACH” and “COOL” only available on some models.

Table 4

DISPLAY

MESSAGE

EXPLANATION

SUPPLEMENTAL INFORMATION

“000”

A user lockout code has been
activated.

A numeric code is required before any temperature adjustment can
be entered. Use the “UP” or “DOWN” arrow to enter code, then select
“MODE” to temporarily unlock Heat Pump. If code is unknown, a re-
set option is available in product manual. Manuals can be
downloaded from www.AquaCal.com.

“ACH”

Auto-Change Over Mode

When this mode is active, the heat pump will automatically switch
between heating and cooling modes to maintain a set temperature
point within

3 degrees. Feature available for Heat & Cool units.

“COOL”

Cooling Mode

Heat Pump is set to cool the water. Feature available for Heat & Cool
units.

“HEAT”

Heating Mode

Heat Pump is set to heat water.

“OFF”

Unit off

Heat Pump can be turned off by using “MODE” button or setting
temperature below 45 degrees. Heat Pump will not allow a set
temperature to be programmed until turned on again.

“xx°”

Current Water Temperature
(Example 78°)

Temperature can be set from 45° F to 104° F. This can be displayed
in Fahrenheit or Celsius depending on programming.

FLO

No water flow through Heat Pump

This can be a normal display depending on system settings. See
“Troubleshooting” if needed.

Table 5

POOL

SPA

78

°

Pool

Spa

Cooling

Desired Temp
Water Temp
Heating

UP

DOWN

MODE

Advertising
This manual is related to the following products: