Hydrotech 7000 Master Programming Mode User Manual
7000 master programming mode

7000 Master Programming Mode
Page 1
NOTE:
1. Set Time of Day Display to 12:01 P.M.
2. Push and Hold the Set Down and Set Up Button for
5 Seconds.
3. Press Extra Cycle Button Once Per Display Until All
Displays Are Viewed and Normal Operation Is
Resumed.
4. Option Setting Display May Be Changed As
Required by Pushing Either the Set Down or Set Up
Button.
5. Depending on Current Valve Programming, Certain
Displays May Not Be Viewed or Set.
With Time of Day Display Set to 12:01 P.M., Push and Hold Set
Up and Set Down Button For 5 Seconds.
US/Metric Display Format
Example: Gallons
[U- -1] = Default
Liters
[U- -2]
Regenerant Flow
Example: Downflow
[dF]
=
Default
Downflow fill first
[dFFF]
Filter
[Fltr]
Regeneration Type
Example: Time Clock Delayed
[7- -1]
Meter Immediate
[7- -2]
Meter Delayed
[7- -3] = Default
Meter Delayed-Variable Brining
[7- -4]
System Capacity
Example: 24 kilograin capacity, Gallon Format
[C-24] = Default
180 degree-liters, Metric Format
[C180]
Feed Water Hardness
Example: 15 grains/gallon
[H-15] = Default
25 degrees, metric
[H-25]
Regeneration Time
Example: 2 o'clock A.M. regeneration time
[2:00] = Default