Cashco DA0 User Manual

Page 7

Advertising
background image

IOM-DA0

7

2. Inboard Leakage Test.

a. Release all loading pressure in cover

dome.

b. Pressurize inlet to 30 psig (2.1 Barg) with

air, GN

2

.

c. Tube outlet to a beaker of water to ob serve

number of escaping gas bubbles.

Inboard leakage path may be via plug/seat or
dynamic side seal.

3. Pressure Containment Test.

a. Pressurize inlet to 200 psig (13.8 Barg)

and outlet and cover dome to 150 psig
(10.3 Barg) with air or GN

2

.

b. Spray liquid lead detector and check all

ex ter nal leak points; i.e. plugged con nec-
tions, and fl ange bolting.

4. Excessive leakage will require disassembly,

examination of sealing elements, correction
of problem, reassembly and retesting.

Advertising