Ii. installation – Cashco 8900 User Manual

Page 2

Advertising
background image

2

IOM-8900 Series

II. INSTALLATION:

Handle the 8900 Series carefully to insure seat
tightness. Units could be damaged by over tightening
the studs or mounting it on a tank nozzle fl ange that
is not horizontal.

Carefully inspect the relief vent to insure that
there are no packing materials inside or around
the vent housing.

Before placing the vent on the tank nozzle, the fl ange
face on the tank and the vent should be inspected.
The standard vent is supplied with fl at face fl anges
and can mate with 150# ASME or API 650 fl anges.

CAUTION

When installing any Valve Concepts venting device,
any safety regulations and procedures appropriate to
the specifi c plant site must be understood and followed
in accordance with that facilities corporate legal and
advisory policies.

FLANGE TYPE

O.D. in.

I.D. in.

B.C. in

Bolt Hole in.

Quantity

16” - 150#

23.50”

15.25’

21.25”

1.13”

16

20 - 150#”

27.50”

19.25”

25.00”

1.25”

20

24” - 150#

32.00”

23.25”

29.50”

1.38”

20

20” - API 650

26.00”

19.25”

23.50”

.75”

16

24” - API

30.00”

23.25”

27.50”

.75”

20

Gasket Dimensions

CAUTION

DO NOT attempt to change pressure settings, either by
adding additional weight to the pallet assembly or by
changing the spring compression without consulting
the factory.

The connecting fl anges must be fl at within 0.015”
(.381 mm), clean and free of scratches, corrosion
and any tool marks.

Inspect the gasket and make sure it is compatible
for the service. It is recommended to use a full
faced gasket to avoid defl ection of the body fl ange.

The vent should be installed using a wire cables
or straps connected to the lifting lugs/eyebolts (39)
located around the fl ange base. This will prevent
any damage to the hood.

Lubricate all studs and nuts with an appropriate
thread lubricant. If stainless steel fasteners are
used, select an anti-seize lubricant such as moly-
disulfi de.

Align the gasket with the bolt circle of the fl ange.

Lower the vent body carefully on the nozzle fl ange;
keep the gasket between the fl anges. Install the
studs and tighten the nuts by hand.

Using an alternating star pattern, tighten all the
fasteners to one-half recommended torque - see
Table 1. Make sure that the fl anges are not distorted
and that the gasket is evenly compressed. Finish
tightening fasteners to torque values in Table 1.

SECTION II

TABLE 1

Flange

Type

Size

Qty

Holes

Bolt

(in)

(UNC)

Torque (ft-lbs)

Raised Face

Flat Face

150# ASME

16”

16

1.000

52

104

20”

20

1.125

63

110

24”

20

1.250

86

148

API # 650

20”

20

0.625

35

53

24”

20

0.625

43

61

Advertising