INSTEON DIN Rail On/Off - 2453-222 (US), 2453-422 (EU), 2453-522 (AUS/NZ) Quick Start User Manual

Quick start guide, Insteon

Advertising
background image

2453-222/2453-422/2453-522 Rev. 12/12/2012 3:39 PM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see www.insteon.com)
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 866-243-8022



Quick Start Guide

INSTEON

®

DIN Rail On/Off

Models: 2453-222, 2453-422, 2453-522

Tools Needed

Slotted #1 screwdriver

• Voltage meter

Wire cutter/stripper

Installing INSTEON DIN Rail

Installation should only be performed by a qualified electrician or a homeowner
who is familiar and comfortable with electrical circuitry. If you have questions,
consult an electrician or call the INSTEON Support Line at

866-243-8022

1)

Turn off breaker/fuse and verify that the power is off

2)

Disconnect wires from existing switch, fixture or outlet and prep all wires to
be connected to DIN rail, with 5/16” (8mm) of bare wire on the ends

3)

Snap module onto DIN rail

4)

Connect wires per diagram which corresponds to your installation

Note: sense lines carry very low current (~0.35mA 240V, ~0.17mA for 120V)

5)

After ensuring wires are firmly connected and that there is no exposed wire, turn on breaker/fuse

After a few seconds, load will turn on and DIN Rail LED will turn green

6)

Test by tapping DIN Rail paddle top and bottom

Load will turn on and off
Din Rail LED will turn green when load is on and red when load is off

7)

If installing a single momentary or dual momentary switch
a) Press and hold set button until it beeps

LED will start blinking green

b) Press and hold set button until it beeps a second time

LED will start blinking red

c) Press and hold set button until it beeps a third time

LED will start blinking green

Line

Neutral

Paddle top

(on)

LED

Fuse (US Only)

Set

button

Sense #2

Connected

load

Sense #1

Paddle bottom

(off)