INSTEON SynchroLinc (2423A5) Quick Start User Manual

Quick-start guide, Synchrolinc, Power-synching insteon

Advertising
background image

Page 1 of 1
Rev. 03-07-2011

Smarthome Limited Warranty – Smarthome warrants to original consumer of this product for a period of 2 years from date of purchase, this product will be
free from defects in material & workmanship & will perform in substantial conformity with its Owner's Manual. Warranty shall not apply to defects caused by
misuse or neglect.
U.S. Patent No. 7,345,998, International patents pending © Copyright 2011
Smarthome, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845



Quick-Start Guide

SynchroLinc

- Power-Synching INSTEON

®

Controller

Model: 2423A5






Introduction

You can use SynchroLinc to create Load Sense scenes to control other
INSTEON devices, based on the power state of the load plugged into
SynchroLinc.

Set

button



Status

LED



Outlet






























*Setup modes will automatically time out after 4 minutes

Installation

1) Plug the desired device (also called the load) into the outlet on the bottom of SynchroLinc
2) Plug SynchroLinc into an unswitched wall outlet

SynchroLinc should beep
The Status LED should turn on solid green or red
After 20 seconds, SynchroLinc should double-beep and enter Calibration Mode*

Complete Instructions, Troubleshooting, and Tech Support

Owner’s Manual:

www.smarthome.com/manuals/2423A5.pdf

Call: INSTEON Gold Support Line at 800-762-7845

Creating a Load Sense Scene

A Load Sense scene allows you to control other INSTEON devices based on the energy level of the device plugged into
SynchroLinc. For example, you could create a scene that turns on your surround sound system when your DVD player (the
load) is turned on.

The scene will be activated when the load turns on. When the load is turned off, all Linked Responders will also turn off. See
the Owner’s Manual for other scene options.
1) At the Responder, set it to the state you wish to be activated from SynchroLinc when the load enters the high power state

(Turn it on if you wish it to be on or off if you wish it to be off when SynchroLinc activates the scene, set brightness levels,
etc.)

2) Set SynchroLinc to Linking Mode* by pressing & holding the Set button until it beeps (3 seconds)

The SynchroLinc Status LED should begin blinking green

3) Press & hold the Responder’s Set button for 3 seconds

SynchroLinc should double-beep and its Status LED should turn on solid green when the load is in its high energy
state and red when it is in its low energy state

4) Confirm that Linking was successfully by turning the load on and off

The Responder should respond appropriately

Calibrating SynchroLinc

1) Make sure the load is off or in its standby state
2) Wait at least 10 seconds, then tap the Set button on SynchroLinc to record the off/low energy state

SynchroLinc should beep

3) Turn the load on, or set to highest energy state
4) Wait at least 10 seconds, then tap the Set button on SynchroLinc once to record the on/high energy state

SynchroLinc should double-beep and its Status LED should turn on solid green when the load is in its high energy
state and red when it is in its low energy state

Product Use Restrictions

Use only as directed in the instructions and within the specifications and
environmental conditions below. Using SynchroLinc in a different manner or
outside the conditions below may defeat the safety features and protection
against electrical shock and fire.

120 Volts AC +/- 10%, 60 Hertz, 15 Amps maximum continuous

Indoor use only

• Temperature

41

° to 104° F (5° to 40° C)

Maximum relative humidity 80% for temperatures up to 87

° F (31° C)

decreasing linearly to 50% relative humidity at 104

° F(40° C)

Altitude up to 6,500 feet (2,000 meters)

Installation Category II

Pollution Degree 2