Table 6. technical data venting – American Water Heater BCL3 85T390 6NOX User Manual

Page 18

Advertising
background image

18

type B gas Vent

multiple gas fired tank-type heaters

When venting multiple tank type heaters using Type b vent

pipe, follow the installation diagram (figure 13) and tables

below which give sizing and data based upon nFPA 54/AnSI

Z223. 2006.

taBle 6. teChniCal data Venting

model BCl3 95t199 6noX
input: 199,000 Btu/hr

total Vent height (feet)

Vent Connector size: 6 inches

6

8

10

15

20

30

50

100

input Btuh/hr

rise

Vent Connector diameter (inches)

199,000

1 Ft.

7

7

7

6

6

6

6

6

199,000

2 Ft.

7

7

6

6

6

6

6

6

199,000

3 Ft.

6

6

6

6

6

6

6

6

number of 199 heaters

Combined input in

thousands of Btu/hr

manifold and Common Vent diameters (inches)

2

398,000

7

7

7

6

6

6

6

6

3

597,000

7

7

6

6

6

6

6

6

4

796,000

6

6

6

6

6

6

6

6

Advertising
This manual is related to the following products: