Locating the water heater, Clearances, Locating the water heater clearances – American Water Heater BCL3 85T390 6NOX User Manual

Page 9: Caution, Fire or explosion hazard

Advertising
background image

9

the water heater must be placed on a metal or wood panel

extending beyond the full width and depth by at least 3 inches

in any direction. If the heater is installed in a carpeted alcove,

the entire floor shall be covered by the panel. Also, see the

DrAInInG requirements in MAInTenAnCe Section.
THe HeATer SHAll be lOCATeD Or PrOTeCTeD SO IT

IS nOT SUbJeCT TO PHYSICAl DAMAGe bY A MOVInG

VeHICle.
FlAMMAble ITeMS, PreSSUrIZeD COnTAInerS Or AnY

OTHer POTenTIAl FIre HAZArDOUS ArTICleS MUST

neVer be PlACeD On Or ADJACenT TO THe HeATer.

OPen COnTAInerS Or FlAMMAble MATerIAl SHOUlD

nOT be STOreD Or USeD In THe SAMe rOOM WITH THe

HeATer.
THe HeATer MUST nOT be lOCATeD In An AreA WHere

IT WIll be SUbJeCT TO FreeZInG.
lOCATe IT neAr A FlOOr DrAIn. THe HeATer SHOUlD

be lOCATeD In An AreA WHere leAKAGe FrOM

HeATer Or COnneCTIOnS WIll nOT reSUlT In DAMAGe

TO ADJACenT AreA Or TO lOWer FlOOrS OF THe

STrUCTUre.
WHen SUCH lOCATIOnS CAnnOT be AVOIDeD, A SUITAble

DrAIn PAn SHOUlD be InSTAlleD UnDer HeATer. Such

pans should be fabricated with sides at least 2” deep, with length

and width at least 2” greater than diameter of heater and must

be piped to an adequate drain. Pan must not restrict combustion

air flow.

ClearanCes

This water heater is approved for installation on combustible

flooring in an alcove with minimum clearance from combustion

construction as indicated in Figure 7 and Table 4.
In all installations the minimum combustible clearances from

vent piping shall be 6” (15.2 cm). Vent piping passing through a

combustible wall or ceiling must be a continuous run (no joints)

and retain 6” (15.2 cm) clearance unless an approved reducing

thimble is used.
A service clearance of at least 24” (61 cm) should be maintained

from serviceable parts.
The units are approved for installation with side, rear and ceiling

clearances as indicated below:

taBle 4. minimum ClearanCes to ComBustiBle or

non-ComBustiBle ContruCtion

Model

"A" right Side "b" left Side "C" back "D" Ceiling

bCl3 95T199

6nOX

0"

0"

0"

12"

0 cm

0 cm

0 cm

30.5 cm

(A)bCl3

85T275 6nOX

0"

0"

0"

12"

0 cm

0 cm

0 cm

30.5 cm

(A)bCl3

85T390 6nOX

0"

0"

0"

12"

0 cm

0 cm

0 cm

30.5 cm

loCating the water heater

Property Damage Hazard

All water heaters eventually leak.

Do not install without adequate drainage.

CAUTION

When installing the heater, consideration must be given to

proper location. location selected should be as close to the

stack or chimney as practicable, with adequate air supply and as

centralized with the piping system as possible.

Fire or Explosion Hazard

Read instruction manual before

installing, using or servicing

water heater.

Avoid all ignition sources if you smell gas.

Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.

Use only the gas shown on the water heater rating label.

Keep ignition sources away from faucets after extended

periods of non-use.

Maintain required clearances to combustibles.

Do not expose water heater controls to excessive gas

pressure.

THere IS A rISK In USInG FUel bUrnInG APPlIAnCeS

SUCH AS GAS WATer HeATerS In rOOMS, GArAGeS Or

OTHer AreAS WHere GASOlIne, OTHer FlAMMAble

lIqUIDS Or enGIne DrIVen eqUIPMenT Or VeHICleS

Are STOreD, OPerATeD Or rePAIreD. FlAMMAble

VAPOrS Are HeAVY AnD TrAVel AlOnG THe FlOOr

AnD MAY be IGnITeD bY THe HeATer’S IGnITer Or MAIn

bUrner FlAMeS CAUSInG FIre Or eXPlOSIOn. SOMe

lOCAl CODeS PerMIT OPerATIOn OF GAS APPlIAnCeS

In SUCH AreAS IF THeY Are InSTAlleD 18” Or MOre

AbOVe THe FlOOr. THIS MAY reDUCe THe rISK IF

lOCATIOn In SUCH An AreA CAnnOT be AVOIDeD.
DO nOT InSTAll THIS WATer HeATer DIreCTlY On A

CArPeTeD FlOOr. A FIre HAZArD MAY reSUlT. Instead

Advertising