Installation and connection, 5 setting dome camera – KT&C KPT-SPDN300NUCH User Manual

Page 12

Advertising
background image

2. Installation and Connection

2.5 Setting Dome Camera

The device can communicate with external switching device such as multiplexer or DVRs by

setting the Rotary switch and Dip switch. Refer to tables below for setting the dome camera ID

and protocol selection. Total length of the cable for communication should not exceed 1km.

2.5.1 Setting the address (ID) of dome camera

To prevent wrong operation and malfunction, each dome camera has a unique address (ID).

The default setting is 0[ID001].

The value of rotary switch is in hexadecimal.

ex) SW301 : A, SW302 : F

0xAF => ID175

* Check appendix sheet

Dome Camera ID Setting (Rotary Switch, SW301, SW302)

X16

X1

SW301

SW302

2.5.2 Setting the protocol of dome camera

Dome Camera Protocol Setting(Dip Switch, SW303)

No1

No2

Protocol

Off

Off

Pelco-D/Pelco-P

Dome Camera Baud Rate Setting (Dip Switch, SW303)

No3

No4

Baud Rate(bps)

Off

Off

2400

Off

On

4800

On

Off

9600

On

On

38400

Dome Camera Termination Setting Off/ON (NO5, Dip Switch, SW303)

12

SW302

SW301

SW303

Advertising