Increment batch count, Reset batch count – CONTREX CX-1010 User Manual

Page 21

Advertising
background image

Page 19

Increment Batch Count

(J7 pins 6, 8)
Digital Input 12

INCREMENT BATCH COUNT is a momentary input.
When it is closed, the CX–1010 increases the internal
batch counter by one increment.

Reset Batch Count

(J7 pins 7, 8)
Digital Input 13

RESET BATCH COUNT is a momentary input. When it
is closed, the CX–1010 resets the internal batch counter
to zero.

Figure 25 Reset Batch Count

RESET BATCH

COUNT

7

8

J7

DI_13

COM

Figure 24 Increment Batch Count

INCREMENT BATCH

COUNT

6

8

J7

DI_12

COM

Positive

Setpoint Value

Negative

Setpoint Value

Setpoint Direction

Open

Setpoint Direction

Closed

Forward

Command

Reverse

Command

Reverse

Command

Forward

Command