5. If the charging lamp and maintenance charging lamp alternately flash the reason for this is

the following:

If the lamps flash a few times per second then the battery is probably sulphated. If the lamp

flashes more than 60 minutes the battery should be replaced.

If the flashing occurs with a few minutes’ interval then the battery has a high self-discharge

and may need to be replaced.

CHARGING PHASES

M300 STARTER has a four step fully automatic charging cycle. At the start of charging the

battery charger delivers maximum current to the battery and the battery voltage increases

constantly to a set level of 14.4V. At this point the voltage will be regulated and kept constant

while the charging current is successively lowered. Once the charging current has dropped

below 0.4A the charger switches to maintenance charging.

If the battery is loaded and the battery’s terminal voltage drops to 12.9V the charger automati-

cally switches back to the beginning of the four step cycle. The charger requires a reverse

voltage from the battery of at least 6V to start the charging cycle, this means that if the battery

is so deeply discharged that the terminal voltage is lower than 6V the charger cannot charge the

battery in question. A normal discharged battery has a terminal voltage of 10.5V.

Charging phases:

Desulphation - Desulphation with pulsing for sulphated batteries.

Bulk - Main charge when 80% of charging takes place. The charger delivers a constant current

until the terminal voltage has risen to the set level.

Absorption - Complete charge up to virtually 100%. The terminal voltage is maintained at the

set level. During this phase the current drops successively so the terminal voltage does not be-

come too high. If the absorption phase has been in progress for more than 18 hours the charger

switches to maintenance charging. This function prevents damage if the battery is faulty.

Pulse - Maintenance charging. State of charge varies between 95% and 100%. The battery

receives a pulse when the voltage drops. Keeps the battery in perfect condition when it is not

used. The charger can be connected for months at a time. If possible, check the water level in

the battery.

TEMPERATURE PROTECTION

M300 STARTER is protected from being overheated. The power will be reduced if the ambient

temperature is raised.

MAINTENANCE

The charger is maintenance free. Note that disassembly of the charger is not permitted and

will void the warranty. If the power cord is damaged, the charger must be left to the reseller for

maintenance. The case can be cleaned with a soft damp cloth and mild cleanser. The charger

should be disconnected from the power while cleaning.

EQUIPMENT

M300 STARTER is delivered with a set of battery leads with battery pole clamps and a set of

battery leads with eyelet terminals.

WARRANTY

CTEK SWEDEN AB, Rostugnsvägen 3, SE-776 70 VIKMANSHYTTAN, SWEDEN provides

a limited warranty to the original purchaser of this product. This limited warranty is not

transferable. The unit is warranted against defective workmanship or materials for 5 years

from the date of purchase. The customer must return the product together with the original

purchase receipt to the place of purchase. This warranty is void if the unit is handled carelessly,

opened or repaired by anyone other than CTEK SWEDEN AB or its authorized representative.

CTEK SWEDEN AB makes no warranty other than this limited warranty and expressly excludes

any implied warranty including any warranty for consequential damages. This is the only

expressed limited warranty and CTEK SWEDEN AB neither assumes nor authorizes anyone to

assume or make any other obligation towards the product other than his limited warranty.

TECHNICAL SPECIFICATION

Model

XS 800

Voltage AC

170–260VAC, 50–60Hz

Back current drain*

< 1Ah/month

Voltage

Charging Voltage Nominal: 12V; 14.4V

Ripple**

Max 50mV rms, max 0.05A

Current

0.8A max

Ambient Temperature -20°C to +50°C, power is reduced automatically at

increased ambient temperature.

Cooling

Natural convection.

Charging cycle

M300 STARTER is a multistage fully automatic charger

Type of batteries

All types of 12V lead-acid batteries (Wet, MF, VRLA,

AGM and GEL).

Battery capacity

1.2–32Ah, up to 100Ah for maintenance.

Dimensions

142 x 51 x 36 mm (L x W x H)

Enclosure class

IP65***

Weight

0.3 kg

*) Back Current Drain is what the charger uses to drain the battery if the power cord is

disconnected.

**) Quality of the current and voltage are very important. High current ripple heats up the

battery and makes the positive electrode age prematurely. High voltage ripple could harm

other equipment connected to the battery. M300 STARTER produces a high quality current and

voltage with very low ripple.

***) If the power connected is the flat European contact type, the battery charger has insulation

class IP63, except in Switzerland where IP65 is valid.

MANUFACTURER’S DECLARATION

CTEK SWEDEN AB, Rostugnsvägen 3, SE-776 70 VIKMANSHYTTAN, SWEDEN. Declares

under sole responsibility that the battery charger M300 STARTER, to which this declaration

relates is in conformity with the following LVD standards: EN60335-1, EN60335-2-29 ac-

cording to the terms of directive 73/23/EEC with the addition of 93/68/EEC. This product also

is in agreement with the following EMC standards: EN55011, EN61000-3-3, EN61000-3-2,

EN55014-1 and EN55014-2 according to the terms of directive 89/336/EEC with the addition of

92/31/EEC and 93/68/EEC.
The charger comes in different models with different types of electrical plugs. The charger with

the flat euro connector is intended for Switzerland.
VIKMANSHYTTAN, SWEDEN 2006-12-12

Börje Maleus, VD

CTEK SWEDEN AB,

Rostugnsvägen 3

SE-776 70 VIKMANSHYTTAN, SWEDEN

Fax: +46 225 30793

www.ctek.com

CHARGING TIME

The table shows the length of time for bulk charging.

Battery size (Ah)

Time to ~80% charge (h)

2

2

8

8

20

20

60

60

20

01