BATTERY SIZE (Ah)

TIME TO 90% CHARGED

8Ah

2h

20Ah

5h

60Ah

16h

READY TO USE

The table shows the estimated time for an empty battery to reach 90%

state of charge (SOC).

Please note that charging times are

longer in low ambient temperatures.

ERROR LAMP

If the error lamp is lit, check the following:

1. Is the chargers positive lead connected to the battery´s

positive pole?

2. Is the charger connected to a 12V LiFePO

4

battery?

3. Has charging been interrupted in STEP 1 or 4?

Restart the charger by pressing the RESET-button. If charging is still

being interrupted, the battery...

STEP 1: ...can not accept charge.

...may be too large for the charger to wake up. Press

RESET-button up to 5 times.

...a paralell load may be connected to the battery. Disconnect

the battery and try again.

STEP 4: ...can not keep charge and may need to be replaced.

POWER LAMP

If the power lamp is lit with a:

1. STEADY LIGHT

The mains cable is connected to the wall socket.

2. FLASHING LIGHT:

The charger has entered the energy save mode. This happens if the

charger isn´t connected to the battery within 2 minutes or the battery on

board UVP (under voltage protection) is activated.

CONNECT AND DISCONNECT THE CHARGER TO A BATTERY

Comfort

Connect

Comfort

Connect

INFO

If the battery clamps are incorrectly

connected, the reverse polarity pro-

tection will ensure that the battery

and charger are not damaged.

For batteries mounted inside a

vehicle

1. Connect the red clamp to the bat-

tery's positive pole.

2. Connect the black clamp to the

vehicle chassis remote from the fuel

pipe and the battery.

3. Connect the charger to the wall

socket.

4. Disconnect the charger from the

wall socket before disconnecting the

battery.

5. Disconnect the black clamp before

the red clamp.

Some vehicles may have posi-

tively earthed batteries.

1. Connect the black clamp to the bat-

tery's negative pole.

2. Connect the red clamp to the vehicle

chassis remote from the fuel pipe and

the battery.

3. Connect the charger to the wall

socket.

4. Disconnect the charger from the

wall socket before disconnecting the

battery.

5. Disconnect the red clamp before the

black clamp.