Figure 7 - unit address planning example – CTI Products MCN RCD System Overview User Manual
Page 25
![background image](/manuals/334806/25/background.png)
MCN System Manual
Hardware Installation
CTI Products, Inc.
68-10833-120
21
Figure 7 shows a system that has three Comparator I/O Modules located in
comparator room A, two Comparator I/O Modules located in comparator room B,
two User Interface Modules located at a maintenance site and two User Interface
Modules located in a dispatch room. For this system, all of the modules in a
single room are set to the same Group number. All modules in comparator room
A are assigned to Group 01. All modules in comparator room B are assigned to
Group 02. The User Interface Modules in the dispatch room are set to Group 80.
The User Interface Modules at the maintenance site are set to Group 81.
With this setup, all of the Comparator I/O Modules are addressed into two
different Groups. This allows plenty of expansion in both comparator rooms, but
since only 2 groups are used, it allows the PCs running the MCN Remote
Comparator Display Software to monitor and control all receivers in the system
from a single screen.
CA-80045-100
MODULE 1
MODULE 0
P/S
T
MODULE 1
MODULE 0
P/S
CONSOLE
MODULE 1
MODULE 0
P/S
COMPARATOR 5
COMPARATOR 4
MODULE 1
MODULE 0
P/S
T
COMPARATOR 1
COMPARATOR 2
MODULE 2
COMPARATOR 3
GROUP 01
GROUP 01
GROUP 01
GROUP 02
GROUP 02
GROUP 80
GROUP 80
GROUP 81
GROUP 81
INTERFACE
USER
DISPATCH ROOM
MAINTENANCE SITE
COMPARATOR ROOM A
COMPARATOR ROOM B
INTERFACE
USER
INTERFACE
USER
Figure 7 - Unit Address Planning Example